African Journal of
Microbiology Research

  • Abbreviation: Afr. J. Microbiol. Res.
  • Language: English
  • ISSN: 1996-0808
  • DOI: 10.5897/AJMR
  • Start Year: 2007
  • Published Articles: 5241

Full Length Research Paper

Bacteriological quality of drinking water obtained from main sources, reservoirs and consumers’ tap in Arba Minch town, Southern Ethiopia

Gemechu Ameya
  • Gemechu Ameya
  • Department of Medical Laboratory Science, College of Medicine and Health Sciences, Arba Minch University, Arba Minch, Ethiopia.
  • Google Scholar
Olifan Zewdie
  • Olifan Zewdie
  • Department of Medical Laboratory Science, College of Medicine and Health Sciences, Wollega University, Nekemte, Ethiopia.
  • Google Scholar
Abdulhakim Mussema
  • Abdulhakim Mussema
  • Department of Medical Laboratory Science, Wochamo University, Hossana, Ethiopia.
  • Google Scholar
Adugna Amante
  • Adugna Amante
  • Department of Medical Laboratory Science, Ambo Hospital, Ambo, Ethiopia.
  • Google Scholar
Birhanie Asmera
  • Birhanie Asmera
  • Department of Medical Laboratory Science, Public Hospital, Addis Ababa, Ethiopia.
  • Google Scholar


  •  Received: 17 April 2018
  •  Accepted: 05 June 2018
  •  Published: 28 June 2018

Abstract

The most common and wide spread health risk associated with drinking water is microbial contamination. The aim of this study is to assess microbial contamination of drinking water, starting from source to distribution systems. Water samples from the Arba Minch town of Southern Ethiopia were collected randomly from the main source before chlorination, reservoir after chlorination and from different points of distribution lines. Total coliforms, fecal coliforms and heterotrophic plate count (HPC) were determined from collected water samples. Coliforms were analyzed by using the most probable number (MPN) method. About 93.3% of collected water samples were contaminated with total coliforms and 16.7% of distributed tap water was contaminated with fecal coliforms. Most of the analyzed water samples had high number of viable bacteria or HPC (>5 log), and total coliforms. The HPC ranged from 1.9 log of bacteria in the chlorinated water in reservoir tank to 8.44 log in the source water before chlorination. Overall, the quality of drinking water suggests that the distribution lines are the most likely point of microbial contamination. Therefore, regular bacteriological monitoring and maintaining residual chlorine in distribution system is mandatory.

Key words: Coliforms, drinking water, heterotrophic plate count, microbiological point of contamination.