Full Length Research Paper
Abstract
A reverse flow injection chemiluminescence (CL) method for the fast and simple determination of vitamin C has been developed. The CL light observed after luminal-H2O2 aqueous solution was added to the on-line formed Br2 solution from mixing of HBr and KBrO3 solutions was inhibited in the presence of Vitamin C. Based on these facts, a determination method of Vitamin c was developed. In order to obtain the optimum experimental conditions, effects of different variables on the chemiluminescence intensity and proposed flow-injection analysis (FIA) system were investigated. The calibration curve obtained under optimum conditions was linear over the range from 1.0 to 16.0 µg/ml with correlation coefficient R = 0.9959 and detection limit of 0.4 µg/ml. The proposed method has been successfully applied to the determination of Vitamin C content in pharmaceutical formulation. The obtained results are in good agreement with an iodimetric method reported in British Pharmacopeia.
Key words: Reverse-FIA, chemiluminescence, vitamin C, pharmaceutical formulation.
Abbreviation
Abbreviations: CL, Chemiluminescence; AA, ascorbic acid; FIA, flow-injection analysis;DDW, deionized-distilled water; RSD, relative standard deviation.
Copyright © 2024 Author(s) retain the copyright of this article.
This article is published under the terms of the Creative Commons Attribution License 4.0